Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Expert Rev Med Devices ; 21(3): 187-196, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38155555

RESUMO

INTRODUCTION: Over the last two decades, mitral transcatheter edge-to-edge repair (M-TEER) has become a safe and effective therapy for severe mitral regurgitation in patients deemed at high surgical risk. AREAS COVERED: This review aims to encompass the most relevant and updated evidence in the field of M-TEER from its inception, focusing on clinical and anatomical features for proper patient and device selection. EXPERT OPINION: Growing operator experience and device iterations have resulted in improved clinical outcomes and an expansion of the therapy to patients with complex anatomies and clinical scenarios. Future investigations are warranted to determine the best management options and the most suitable device for every patient with MR.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seleção de Pacientes , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-38069980

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is associated with an increased mortality. Previous studies have analyzed predictors of TR progression and the clinical impact of baseline TR. However, there is a lack of evidence regarding the natural history of TR: the pattern of change and clinical impact of progression. OBJECTIVES: The authors sought to evaluate predictors of TR progression and assess the prognostic impact of TR progression. METHODS: A total of 1,843 patients with at least moderate TR were prospectively followed up with consecutive echocardiographic studies and/or clinical evaluation. All patients with less than a 2-year follow-up were excluded. Clinical and echocardiographic features, hospitalizations for heart failure, and cardiovascular death and interventions were recorded to assess their impact in TR progression. RESULTS: At a median 2.3-year follow-up, 19% of patients experienced progression. Patients with baseline moderate TR presented a rate progression of 4.9%, 10.1%, and 24.8% 1 year, 2 years, and 3 years, respectively. Older age (HR: 1.03), lower body mass index (HR: 0.95), chronic kidney disease (HR: 1.55), worse NYHA functional class (HR: 1.52), and right ventricle dilation (HR: 1.33) were independently associated with TR progression. TR progression was associated with an increase in chamber dilation as well as a decrease in ventriculoarterial coupling and in left ventricle ejection fraction (P < 0.001). TR progression was associated with an increased cardiovascular mortality and hospitalizations for heart failure (P < 0.001). CONCLUSIONS: Marked individual variability in TR progression hindered accurate follow-up. In addition, TR progression was a determinant for survival regardless of initial TR severity.

3.
Expert Rev Cardiovasc Ther ; 21(10): 703-712, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37815845

RESUMO

INTRODUCTION: With the expanding indications of transcatheter aortic valve replacement (TAVR) to younger and low-risk patients, the life expectancy of patients currently undergoing TAVR will likely outlive the durability of transcatheter bioprosthesis. Consequently, the number of failed transcatheter bioprosthesis requiring surgical valve explant or redo TAVR is expected to increase. AREAS COVERED: The aim of this review is to provide an updated overview of redo TAVR for treating degenerated transcatheter bioprosthesis, focusing on pre-procedural planning, potential challenges of coronary reaccess during TAVR-in-TAVR and main outcomes of TAVR explant and redo TAVR. EXPERT OPINION: Patient-tailored device selection and individualized implantation height should be carefully assessed during the index TAVR procedure (weighting between pacemaker avoidance and the potential risk of coronary occlusion in future TAVR-in-TAVR). Future prospective studies comparing safety and clinical outcomes between redo TAVR vs TAVR explant are eagerly awaited.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
5.
J Clin Med ; 12(18)2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37762965

RESUMO

Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for patients aged ≥75 years with severe aortic stenosis. Preoperative anemia is present in a large proportion of patients and may increase the risk of post-procedural complications. The purpose of this prognostic systematic review was to analyze the impact of baseline anemia on short- and mid-term outcomes following TAVR. A computerized search was performed on PubMed and Web of Science databases for studies published between January 2013 and December 2022. Primary outcomes were 30-day need for transfusion, acute renal failure, 30-day and mid-term mortality, and readmission during the first year post-TAVR. Data were analyzed via random effects model using inverse variance method with 95% confidence intervals. Eleven observational studies met our eligibility criteria and included a total of 12,588 patients. The prevalence of baseline anemia ranged between 39% and 72%, with no relevant sex differences. Patients with preprocedural anemia received more blood transfusions [OR: 2.95 (2.13-4.09)]), and exhibited increased rates of acute kidney injury [OR:1.74 (1.45-2.10)], short-term mortality [OR: 1.47 (1.07-2.01], and mid-term [OR: 1.89 (1.58-2.25)] mortality following TAVR compared with those without anemia. Baseline anemia determined an increased risk for blood transfusion, acute kidney injury, and short/mid-term mortality among TAVR recipients.

7.
J Clin Med ; 12(12)2023 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-37373808

RESUMO

BACKGROUND: The timing and selection of optimal candidates for mitral transcatheter edge-to-edge valve repair remains to be fully determined, especially in cases with severely depressed left ventricular ejection fraction (LVEF). The objective of this study is to evaluate the prognostic value of myocardial strain (LVGLS) in this setting. METHODS: Retrospectively, 172 consecutive patients with LVEF ≤40% and severe MR treated with MitraClip were included. Four groups were generated according to the LVEF (<30% or ≥30%) and median LVGLS. The primary end-point was cardiovascular mortality. RESULTS: Procedural success was high (96.5%) and complications were rare. At one-year follow-up, 82.5% of patients maintained MR grade ≤2, 79.2% were at a NYHA class ≤II and a reduction of 80% in heart failure admissions was observed in all groups. Interestingly, among patients with a more depressed LVEF, LVGLS was found to be an independent predictor for cardiovascular mortality (HR: 3.3; 95% CI: 1.1-10, p = 0.023). CONCLUSIONS: Mitral valve repair with MitraClip is safe and it improves the mid-term functional class of patients regardless of LVEF. LVGLS can help in the selection of optimal candidates and timing for this procedure, as well as in the recognition of those patients with worse prognoses.

8.
Rev Esp Cardiol (Engl Ed) ; 76(10): 767-773, 2023 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36804557

RESUMO

INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
9.
Rev. esp. cardiol. (Ed. impr.) ; 76(1): 25-31, Ene-Feb. 2023. tab, graf, ilus
Artigo em Espanhol | IBECS | ID: ibc-214450

RESUMO

Introducción y objetivos: PASCAL es un dispositivo novedoso de terapia mitral transcatéter basada en la reparación borde a borde. Algunas características únicas podrían tener un impacto relevante en sus resultados. Hay pocos datos sobre los resultados clínicos en registros de la vida real. El objetivo de este estudio es publicar la experiencia ibérica precoz (centros de España y Portugal) del sistema PASCAL. Métodos: Se incluyó prospectivamente a los pacientes tratados consecutivamente de insuficiencia mitral (IM) grave sintomática en 10 centros. El objetivo primario de eficacia fue el éxito técnico y el grado de regurgitación al alta. El objetivo primario de seguridad fueron los eventos adversos mayores (MAE) a 30 días. Resultados: Se incluyó a 68 pacientes (75 [68-81] años, 38% mujeres, EuroSCORE II 4,5%). La IM fue degenerativa en el 25% de los casos, funcional en el 65%, y mixta en el 10%. El 71% de pacientes estaban en clase funcional New York Heart Association (NYHA)≥III. El éxito técnico fue del 96% y la captura independiente se usó en el 73% de los procedimientos. Toda la población tratada obtuvo una IM al alta≤2+ (100%) y no hubo muertes intrahospitalarias. A los 30 días, los MAE fueron del 5,9%, la mortalidad global del 1,6%, el 98% estuvieron en clase NYHA≤II y el 95% tuvieron IM≤2+ (p <0,001). Conclusiones: El sistema PASCAL de terapia transcatéter mitral fue efectivo y seguro, con elevado éxito técnico y baja tasa de MAE. A los 30 días la IM se redujo significativamente, y hubo una mejoría en la clase funcional.(AU)


Introduction and objectives: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. Methods: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. Results: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). Conclusions: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.(AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Mitral , Efeitos Adversos de Longa Duração , Equipamentos e Provisões , Doenças das Valvas Cardíacas , Cardiologia , Espanha , Doenças Cardiovasculares , Portugal
10.
Rev Esp Cardiol (Engl Ed) ; 76(1): 25-31, 2023 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35691867

RESUMO

INTRODUCTION AND OBJECTIVES: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. METHODS: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. RESULTS: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). CONCLUSIONS: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento
13.
JACC Case Rep ; 4(12): 727-731, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35734523

RESUMO

An 80-year-old woman with mitral valve repair failure was admitted with hemolytic anemia secondary to the impact of a regurgitant jet on the annuloplasty ring. Transcatheter repair to treat both mitral regurgitation and hemolysis was favored because of surgical risk. Transcatheter edge-to-edge repair represents an alternative for treating hemolysis associated with mitral regurgitation. (Level of Difficulty: Advanced.).

14.
JACC Case Rep ; 4(11): 666-670, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35677788

RESUMO

Sinus contrast material retention after transcatheter aortic valve replacement (TAVR) is a rare phenomenon that may reflect an increased risk for thrombotic complications. We present 3 cases of persistent contrast agent retention in the sinus of Valsalva during the TAVR procedure that portend the occurrence of embolic stroke or bioprosthetic valve thrombosis. (Level of Difficulty: Advanced.).

15.
Rev Esp Cardiol (Engl Ed) ; 75(12): 1001-1010, 2022 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35272968

RESUMO

INTRODUCTION AND OBJECTIVES: Transcatheter edge-to-edge repair (TEER) should be considered in patients with heart failure and secondary mitral regurgitation (MR). Angiotensin receptor-neprilysin inhibitors (ARNIs) have been demonstrated to improve prognosis in heart failure. We aimed to evaluate the impact ARNIs on patient selection and outcomes. METHODS: The population of the Spanish TEER prospective registry (March 2012 to January 2021) was divided into 2 groups: a) TEER before the ARNI era (n=450) and b) TEER after the recommendation of ARNIs by European Guidelines (n=639), with further analysis according to intake (n=52) or not (n=587) of ARNIs. RESULTS: A total of 1089 consecutive patients underwent TEER for secondary MR. In the ARNI era, there was a reduction in left ventricle dilation (82mL vs 100mL, P=.025), and better function (35% vs 38%, P=.011). At 2 years of follow-up, mortality (10.6% vs 17.3%, P <.001) and heart failure readmissions (16.6% vs 27.8%, P <.001) were lower in the ARNI era, but not recurrent MR. In the ARNI era, 1- and 2-year mortality were similar irrespective of ARNI intake but patients on ARNIs had a lower risk of readmission+mortality at 2 years (OR, 0.369; 95%CI, 0.137-0.992; P=.048), better NYHA class, and lower recurrence of MR III-IV (1.9% vs 14.3%, P=.011). CONCLUSIONS: Better patient selection for TEER has been achieved in the last few years with a parallel improvement in outcomes. The use of ARNIs was associated with a significant reduction in overall events, better NYHA class, and lower MR recurrence.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Neprilisina , Humanos , Insuficiência Cardíaca/tratamento farmacológico , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/tratamento farmacológico , Insuficiência da Valva Mitral/cirurgia , Neprilisina/antagonistas & inibidores , Receptores de Angiotensina , Resultado do Tratamento
17.
EuroIntervention ; 17(16): 1300-1309, 2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-34483091

RESUMO

BACKGROUND: MAC is commonly found in patients affected with MR, and it is associated with high morbidity, mortality and worse cardiac surgical outcomes. Transcatheter edge-to-edge repair could be an alternative treatment, although there is little evidence in this population. AIMS: The aim of this study was to analyse the safety, efficacy and durability of MitraClip implantation in patients affected with mitral regurgitation (MR) and mitral annulus calcification (MAC). METHODS: We analysed the outcomes of 61 suitable patients affected with severe MR and moderate or severe MAC (the "MAC" group) and 791 patients with no or mild MAC (the "NoMAC" group) treated with the MitraClip device. RESULTS: Procedural success was similar (91.8% vs 95.1%, p=0.268, in MAC and NoMAC, respectively), with a very low rate of complications. At one-year follow-up, 90.6% of MAC and 79.5% of NoMAC patients had MR grade ≤2 (p=0.129), 80% in both groups remained in NYHA Functional Class ≤II, and a significant reduction in cardiac readmissions was observed (65% vs 78% in MAC vs NoMAC, p=0.145). One-year mortality tended to be higher in MAC patients (19.7% vs 11.3%, p=0.050), with no difference in cardiovascular mortality (15.3% vs 9.2%, p=0.129). CONCLUSIONS: MitraClip use in selected patients with moderate or severe MAC is safe, feasible and achieves good clinical and echocardiographic results at one-year follow-up.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Índice de Gravidade de Doença , Resultado do Tratamento
18.
Int J Cardiol ; 345: 29-35, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34610357

RESUMO

BACKGROUND: Isolated atrial fibrillation can cause mitral regurgitation (MR) in patients with normal left ventricular systolic function and no organic disease of the mitral valve. Little information is available regarding outcomes of Mitraclip in patients with atrial functional mitral regurgitation (AFMR). We aimed to evaluate 12-month clinical and echocardiographic outcomes of transcatheter mitral valve repair (TMVR) with MitraClip in patients with AFMR compared to those with ventricular functional or degenerative/mixed MR. METHODS: Registry-based analysis of all consecutive patients who underwent TMVR and were included in the Spanish Registry of Mitraclip. Changes in MR and NYHA functional class, and a combined endpoint including all-cause mortality and hospitalizations due to heart failure were the main outcomes. RESULTS: Overall, 1074 (69.1% male, 73.3 ± 10.2 years-old) patients were analyzed in this report. 48 patients (4.5%) presented AFMR. AFMR was significantly reduced after TMVR, with a procedural success rate of 91.7%, and this reduction persisted at 12-month (p < 0.001). Patients with AFMR showed a significant functional improvement at 6- and 12-month follow-up in our series (baseline: NYHA III 70.8% IV 18.8% vs. 1-year: NYHA III 21.7% IV 0%; p < 0.001). The probability of survival free of readmission for heart failure and all-cause mortality within the first year after TMVR was 74.9%. Procedural and clinical outcomes, as well as recurrent rates of MR were similar acutely and at 1-year compared to other etiologies. CONCLUSION: TMVR in patients with AFMR showed no significant differences compared to ventricular functional or degenerative/mixed MR regarding MR reduction or clinical outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Ecocardiografia , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
19.
EuroIntervention ; 17(11): e944-e952, 2021 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-34219668

RESUMO

BACKGROUND: Cardiac computed tomography angiography (CCTA) appears to be an appropriate imaging technique for device surveillance after left atrial appendage occlusion (LAAO). However, the available experience is limited. AIMS: The aim of this study was to determine the prevalence, mechanisms and clinical impact of left atrial appendage (LAA) patency and device-related thrombosis (DRT) following LAAO utilising a novel CCTA-based classification. METHODS: Consecutively enrolled patients who underwent LAAO with an AMPLATZER device were followed up with CCTA. Mechanisms and frequency of residual patency were evaluated and correlated with clinical events. Atrial-side device thrombus, device positioning and presence of signs of device stability were also analysed. RESULTS: A total of 137 patients were included. LAA patency was observed in 56.9% (n=78). Mechanisms and frequency of patency were: malapposition of proximal segment of the device lobe (55.1%), peri-device leak (PDL, 34.6%) and fabric permeability (5.8%). Lobe-LAA axis misalignment was the only independent predictor of device patency after LAAO (HR 38.3, 95% CI: 13.6-107.0; p<0.001). After a median follow-up of 638 days, patency was not associated with an increased risk of death (all-cause or cardiovascular death) or cerebral/peripheral embolism regardless of its mechanism. Any degree of hypo-attenuated thickening (HAT) was found in 16.8% (n=23) of patients, of whom 16 (11.7%) had low-grade HAT and 7 (5.1%) had high-grade HAT or definite DRT. Complete sealing was associated with increased rates of low-grade HAT. CONCLUSIONS: LAA patency on CCTA follow-up is a frequent phenomenon due to malapposition of the proximal segment of the device lobe, PDL or fabric permeability. Patency was not associated with adverse outcomes. Low-grade HAT may be related to a benign, uneventful, endothelialisation process favoured by complete LAAO.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Trombose , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Ecocardiografia Transesofagiana , Humanos , Prevalência , Dispositivo para Oclusão Septal/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...